Reviews Thermocouple K

Bakers Pride M1296X 72 Long T46 Thermocouple

  • K-type Thermocouple wire for making thermocouple or extension wire, up to 752 °F (400 °C).
  • Chromel / Alumel type K thermocouple wire with Standard Accuracy: +/- 2.2 °C or +/- .75%.
  • The K-type wires are AWG 24 (0.51 mm) in diameter.
  • ANSI color coded braided fiberglass insulation, red = -, yellow = +.
  • 10 yard ( 30 ft ) roll, wire is flexible and easy to bend to shape.
Check Stock

Digital pyrometer F,C pottery ceramic glass kiln Sensor Thermometer Thermocouple

  • Digital Pyrometer Temperature range: -50°C to 1300°C ( -58°F to 2372°F).
  • Ceramic thermocouple Temperature range: -50°C to 1300°C ( -58°F to 2372°F).
  • Included Pyrometer and 2 type K thermocouple ( One 3" K type thermocouple(-50 to 400°C) and one Kiln K type (-50 to 1300°C)).
  • Decimal or round number display selectable (decimal range is -58.0F to999.9F and round number range is -58F to 2372F).
  • Shipping to USA is 3-6 business days. For more information please go to our website Thermomart.
Check Stock

Cooper-Atkins 93230-K Thermocouple Thermometer (Thermocouple K Type Thermometer) - EconoTemp Combo Pack

  • Thermocouple K Type Thermometer - Includes 32311 thermocouple thermometer, wall bracket, and DuraNeedle probe 50336-K. For foodservice and general purpose temperature monitoring..
  • Accurate Thermocouple Thermometer - Temperature range from -40 to 500 degrees Fahrenheit, precise to +/- 2 degrees Fahrenheit across entire range..
  • DuraNeedle 2 Second Response Time - Includes DuraNeedle 50336-K probe with ultra-fast response time. Features easy to read digital display and 10 minute auto shutoff..
  • Cooper-Atkins Corporation - Headquartered in Middlefield, CT, Cooper-Atkins has been a leading manufacturer of quality time, temperature, and humidity instruments serving the Foodservice, HVAC and Healthcare markets since 1885..
Check Stock

Fluke 51 II Single Input Digital Thermometer

  • Thermocouple thermometer for use in applications requiring a broad range of temperatures, including furnaces, kilns, freezers, and other industrial applications.
  • Measures temperatures in celsius, fahrenheit, or kelvin via a type k, type j, type t, or type e thermocouple probe.
  • Includes a type k bead thermocouple probe with a 40" cable that measures from minus 40 to +260 degrees c ( minus 40 to +500 degrees f).
  • Provides the relative time of minimum, maximum, and average temperature measurements for monitoring.
  • Conforms to nist standards for compliance with regulations.
Check Stock

2 Pcs Digital 2 Channels K Type Thermometer with 8 Thermocouples (Wire and Stainless Steel) -50~1300°c (-58~2372°f) Dual Measurement Meter Sensor Handheld HVAC Thermometer High Temperature Pyrometer

  • High Accuracy: reading accuracy (±0.1°C ±0.4), fast response using K type thermocouple probe, this digital temperature gauge will bring you a lot of convenience.
  • You will get 2 pcs of K type thermometers, 4 pcs of wire thermocouples and stainless steel thermocouples.
  • Multiple Temperature Display: in addition to the max/ min/ average, data hold, and auto power off functions, this hand held temperature reader is specially designed with a "T1-T2" calculation function, making it easy for the user to find the difference between two samples.
  • ​Portable and Practical: powered by battery, this thermometer with probe is portable and practical, operate it with 6 simple buttons with clear instructions, suitable for beginners and skilled users.
  • Plus, the removable silicone rubber cover protects your device from accidental drops.
  • It is factory calibrated and factory reset, and any standard K type thermocouple connector can be applied to replace the included thermocouple when needed.
  • Wide Measurement Temperature Range: mainframe range of digital k type thermometer is about -50°C ~ 1300°C (-58°F ~ 2372°F).
Check Stock

ennoLogic Volt mA Thermocouple Loop Process Calibrator eC370T - 0-20V and 4-20mA Simulator – Portable Millivolt mA and Temperature Signal Generator and Meter for Transmitters Current Loops PLC

  • VERSATILE AND ACCURATE VOLT MA THERMOCOUPLE CALIBRATOR: Signal generator, simulator and volt / mA meter for calibrating, testing and repairing milliamp loops, thermocouples, PLC, temperature control and HVAC systems. Easily generate precise test signals for current and voltage devices (mA, mV, V, Celsius and Fahrenheit ranges)..
  • NUMERIC KEYPAD for ease and flexibility in setting output signals configuring options. HOTKEY programming for each numeric key (long-press immediately outputs user-configured voltage, current or temperature signal). RAMP AND LADDER OUTPUT FUNCTIONS can be custom configured. BUILT-IN 24V LOOP SUPPLY lets you power and read a device or transmitter without needing another multimeter. This greatly simplifies testing 2-wire current loops..
  • MEASURE VOLTAGE OUTPUT SIGNALS from process devices and sensors with two input ranges of 0-100mV (0.01mV resolution, 0.06% accuracy) and 0-20V (1mV resolution, 0.08% accuracy). MEASURE CURRENT TRANSMITTERS within a range of 0 to 24mA with 0.001mA resolution and 0.08% accuracy. MEASURE THERMOCOUPLE TEMPERATURES within a range of -250°C to +1800°C and resolution of ±0.7°C to ±2°C (range and resolution depends on thermocouple type, supported are type K, J, E, T, N, S, R, and B.).
Check Stock

Fluke - FLUKE-52-2 60HZ 52-2 60HZ Dual Input Digital Thermometer

  • Thermocouple thermometer for use in applications requiring a broad range of temperatures, including furnaces, kilns, freezers, and other industrial applications.
  • Measures temperatures in Celsius, Fahrenheit, or Kelvin via a Type K, Type J, Type T, or Type E thermocouple probe.
  • Includes a Type K bead thermocouple probe with a 40" cable that measures from -40 to +260 degrees C (-40 to +500 degrees F).
  • Provides the relative time of minimum, maximum, and average temperature measurements for monitoring.
  • Conforms to NIST standards for compliance with regulations.
Check Stock

DANOPLUS High Accuracy Digital K-Type Thermocouple Thermometer (-50~1300°C) with Dual Channels 4 Probes (Wired & Stainless Steel) Handheld High Temperature Kelvin Scale Meter Tester

  • Designed to work with 2 external K-Type thermocouples for high-temperature measurement ranging from -50 ~ 1300°C (-58 ~ 2372°F)..
  • Comes with built-in microcontroller software & dual thermocouple input terminals that enable simultaneous measurement of two samples.
  • Precision: Reading Accuracy (±0.1°C ±0.4) & fast response with K-Type Thermocouple Probes.
  • Comes with a removable silicon rubber holster to protect your device from an accidental drop.
  • Practical - any standard K-Type thermocouple connectors can be used to replaced the included thermocouples when it needed a replacement.
Check Stock

K Type Thermocouple Temperature Thermocouple Sensor Temperature Detector Temperature Gauge with M4 Thread for 3D Printer Temperature Sensor

  • Type K (chromel–alumel) is the most common general-purpose thermocouple with a sensitivity of approximately 41 µV/°C.[10] It is inexpensive, and a wide variety of probes are available in its −200 °C to +1350 °C (−330 °F to +2460 °F) range. Type K was specified at a time when metallurgy was less advanced than it is today, and consequently characteristics may vary considerably between samples. One of the constituent metals, nickel, is magnetic.
  • a characteristic of thermocouples made with magnetic.
  • They operate very well in oxidizing atmospheres. If, however, a mostly reducing atmosphere (such as hydrogen with a small amount of oxygen) comes into contact with the wires, the chromium in the chromel alloy oxidizes. This reduces the emf output, and the thermocouple reads low. This phenomenon is known as green rot, due to the color of the affected alloy. Although not always distinctively green, the chromel wire will develop a mottled silvery skin and become magnetic. An easy way to check for t.
  • Hydrogen in the atmosphere is the usual cause of green rot. At high temperatures, it can diffuse through solid metals or an intact metal thermowell. Even a sheath of magnesium oxide insulating the thermocouple will not keep the hydrogen out..
Check Stock

Fluke 52-2 Dual Input Digital Thermometer, 3 AA Battery, -418 to 2501 Degree F Range, 60 Hz Noise Rejection

  • Thermocouple thermometer for use in applications requiring a broad range of temperatures, including furnaces, kilns, freezers, and other industrial applications.
  • Measures temperatures in Celsius, Fahrenheit, or Kelvin via a Type K, Type J, Type T, or Type E thermocouple probe.
  • Includes a Type K bead thermocouple probe with a 40" cable that measures from -40 to +260 degrees C (-40 to +500 degrees F).
  • Provides the relative time of minimum, maximum, and average temperature measurements for monitoring.
  • Conforms to NIST standards for compliance with regulations.