Fafeicy 12-Channel DC12-36V PLC Signal Amplifier Board Isolation Relay Module Amplifier Board with NPN Input PNP Output

  • Protection function: The relay can effectively avoid system instability caused by mutual interference, effectively protect the output node of the PLC, ensure the normal transmission of the signal, and thereby protect the relay..
  • Uses: The relay module can be used to protect the PLC internal relays, which can directly replace traditional relays, reducing maintenance time and cost.
  • Stable performance: The signal amplifier is made of high-quality electronic components with stable and reliable performance..
  • Easy to install: It is recommended to design to make drilling and module installation more convenient..
  • After-sales service: We strive to provide you with the highest quality product and the best customer experience, if you're not entirely satisfied, please just feel free to contact us at any time..
Check Stock

Agatige Frequency to Voltage Converter Module, 0-10Khz to 0-10V F/V Digital to Analog Converter Conversion Module

  • FUNCTION: The frequency of the pulse signal 0HZ to 10KHZ converts into an analog voltage signal of 0-10V. Can be used to interface switching between the PLC and the frequency converter, or interface matching such as the matching of motion control card and inverter control..
  • FEATURES: Input pulse level is 5V 12V 24V, which can be directly entered without serial resistor. The input signal frequency must maintain more than 0.5 seconds..
  • ANTI-INTERFERENCE: Conversion module's signal inputs with optical coupling isolation, which can ensure that the capability of anti-interfence..
  • APPLICATION: Frequency to Voltage Converter Module Can be used for industrial control panel PLC or other signal interface switching.
  • MAJOR SPECIFICATIONS: Output current: 5MA,Voltage: 0-10V, Input pulse level: 5V 12V 24V, Frequency: 0 to 10KHZ..
Check Stock

Xiuxin 2pcs 5V 8 Channel Relay Module Board for Arduino PIC AVR DSP ARM

  • 2pcs/lot 8 Channel relay module board, Working voltage: 5V.
  • This board is for Arduino PIC AVR DSP ARM.
  • Support all single-chip microcomputer control,Industrial circle,PLC controller,Household intelligent control.
  • Relay output maximum contact is AC250V 10A and DC30V 10A.
  • Widely used for all MCU control, industrial sector, PLC control, smart home control..
Check Stock

Level Translator 5V/24V, 8 Channel NPN/PNP to NPN Level Conversion Module, Level Conversion Board, Voltage Level Converter Board 10MHZ

  • 【Convert Input Level Signal】The module can convert input 5V level signal to 24V level signal, or convert input 24V level signal to 5V level signal..
  • 【 Anti-interference】It can also convert signal 5V to 5V, or 24V to 24V level, and isolate input signal and output signal through optocoupler, which can improves anti-interference ability of circuit..
  • 【Set by Dip Switch】Input level can be set by DIP switch, 24V level output is NPN OC output, output current is 100mA..
  • 【Strong Driving Ability】It has conversion and amplification circuit, good wave, strong driving ability..
  • 【PLC Interface Standards】Compatible with a common-cathode or common-anode input connection, matching European and Japanese PLC interface st Plc Interface Standardsandards..
Check Stock

YVO Optocoupler Isolation Board,4 Channel Optocoupler Isolation Module PLC Signal Level Voltage Conversion Board,Can be Used for Signal Isolation,Signal Level Voltage Conversion (24V to 5V)

  • 【Widely Use】: Our optocoupler isolation board can be used for signal isolation, PLC signal level converting, level conversion between single-chip microcomputer, PLC and other signals, PNP / NPN signal to NPN signal, signal level voltage conversion and other purposes..
  • 【20K Limit Switching Frequency】: The maximum switching frequency of our optocoupler isolation is 20K..
  • 【Easy To Recognise】: Each channel of our optocoupler isolator module has been equipped with indicator, easier to recognise the working status..
  • 【Size Parameters】: Module Dimensions: 72*55*18mm (length*width*height). Mounting Hole Size: 64*47mm. Mounting Hole Diameter: 3mm..
  • 【SHOPPING WITH CONFIDENCE】: We are committed to providing you with quality services. If you have any question, please feel free to contact us by sending emails.We will provide after-sales service until you are satisfied..
Check Stock

DC12-36V 16 Channel PLC Amplifier Board,PLC Signal Amplifier Board,Isolation Relay Module,NPN Input PNP Output,Drilling,PCB Module Rack Installation

  • Can be used to protect PLC internal relays..
  • Effectively avoid system instability caused by mutual interference..
  • Effectively protected the output nodes of the PLC..
  • Can directly replace traditional relays, reducing maintenance time and costs..
  • Hole punching and PCB module mounting are more convenient..
Check Stock

Painless Performance 80132 Single Pole, Double Throw Relay, 40 Amp

  • ★ The 8-channel relay module is equipped with transistors, diodes and optocouplers to switch higher loads safely, reliably and with little power. The module is also equipped with generously dimensioned relays in order to be able to reliably carry out many switching processes..
  • ★ 5V 8-channel relay module, each relay requires 70mA for switching (switching capacity AC: max. 250V / 10A.
  • ★ 5V 8-channel relay module can be controlled directly with a microcontroller Raspberry Pi, Arduin, 8051, AVR, PIC, DSP, ARM, ARM, MSP430, TTL logic, etc..
  • ★ The relay acts as a switch that responds to a signal from the Arduin. Because of this, it is widely used in IoT projects to control lights and other electronic devices..
  • ★ Application: MCU control, PLC control, industrial area, smart home.If you need this relay, you can buy it directly. If there is a problem during use, you can contact us at any time to refund or replace it..
Check Stock

GCAN-205 Modbus TCP to CAN Converter, Allows User to Connect Some ModTCP Master with an existing CAN Network

  • The GCAN-204 is a CAN to Modbus RTU Slave Converter with one Serial interface and one CAN interface. It allows user to connect some Modbus Master (for example: PLC, HMI, etc) with an existing CAN network. It has integrated isolation protection module and easier to install with DIN-rail..
  • CAN industrial automation control system.
  • The serial communication device is connected to CAN-bus.
Check Stock

PC Interface Controller

  • 【One-year after-sale warranty】The PWM to voltage module converts PWM digital signals to 0 to 10V analog signals. It can be used to switch the signal interface of PLC or other industrial control board. Adjust the output voltage by adjusting the PWM duty cycle. The module is small in size and easy to apply in different places.003cbr003e.
  • Using MCU embedded technology. Easy to operate, can be fine-tuned by potentiometer.003cbr003e.
  • Select the PWM signal input level range by short circuit. The module is small, easy to carry and easy to use.003cbr003e.
  • (current greater than 100mA),PWM signal receiving frequency range: 1KHZ-3KHZ.
  • When power on for the first time, it is best to do a calibration and debugging: find a signal with a 50% duty cycle and connect it to PWM and GND. Jumper caps set the corresponding voltage range. When the frequency is 1KHZ-3KHZ, use a multimeter to measure the two ports of VOUT and GND. At this time, the meter displays about 5V. Adjust the potentiometer on the board so that the multimeter displays 5.00v.003cbr003e.
Check Stock

Isolation Amplifiers Isolated Modulator (5 pieces)

  • ➤【DC12-32V】- This isolation module need two complete independent DC12-32V power supply..
  • ➤【Main function】- Main function is input 0-10V analog voltage signal,after isolation, output 0-10V analog voltage signal..
  • ➤【Scope of Application】- Used to isolate high voltage or strong interference voltage or current (voltage) signal then transferred to PLC or controller MCU, isolating controlling end and controlled end, to assure stability and anti-interference ability of system..
  • ➤【Use】- It will has better performance if install this module and controller in a metal box and box is grounded..
  • ➤【Note】- The potentiometer is used to amend corresponding relation of output voltage. Output voltage can be fine adjusted and calibrated, normally it has already been calibrated..