- 【One-year after-sale warranty】The PWM to voltage module converts PWM digital signals to 0 to 10V analog signals. It can be used to switch the signal interface of PLC or other industrial control board. Adjust the output voltage by adjusting the PWM duty cycle. The module is small in size and easy to apply in different places.003cbr003e.
- Using MCU embedded technology. Easy to operate, can be fine-tuned by potentiometer.003cbr003e.
- Select the PWM signal input level range by short circuit. The module is small, easy to carry and easy to use.003cbr003e.
- (current greater than 100mA),PWM signal receiving frequency range: 1KHZ-3KHZ.
- When power on for the first time, it is best to do a calibration and debugging: find a signal with a 50% duty cycle and connect it to PWM and GND. Jumper caps set the corresponding voltage range. When the frequency is 1KHZ-3KHZ, use a multimeter to measure the two ports of VOUT and GND. At this time, the meter displays about 5V. Adjust the potentiometer on the board so that the multimeter displays 5.00v.003cbr003e.
Check StockAnalog Voltage to PWM Signal Converter, 0-5V/0-10V Analog Input Voltage to 0-100% PWM Signal 2KHZ-20KHZ Converter Module,for PWM Motor Speed Control Interface Circuit Activity
- Voltage to PWM Signal Converter Module: This module can convert 0-5V or 0-10V analog input voltage into 0-100% PWM signal..
- Wide Application: This module is widely used for PWM motor speed control interface circuit, instrumentation AD interface conversion, and other applications that need convert voltage to PWM signal..
- PWM Signal Frequency Range: The PWM signal frequency range is 2KHZ-20KHZ, maximum is 20KHZ, default minimum is 2KHZ,Hyuduo is committed to providing customers with high-quality products and thoughtful service..
- Setable Output Frequency: The default function of this module is converting 0-10V into 0-100% 2KHZ PWM signal, but the output frequency can be set by adjusting potentiometer as needed,stable and reliable performance, practical, easy to operate and use, has a long service life..
- Two Kinds of PWM Signal: There are two kinds of PWM signal, PNP-PWM output and NPN-PWM output. The PNP-PWM output is only 5V level, NPN-PWM output is 5V and 24V level,If you have any problem,please contact us, we will strive to provide you with satisfactory service!.
Check StockLANTRO JS RF WideBand Amplifier 433MHz 22dB High Gain Low Noise LNA Amplifier
- 【Product Parameters】- Working Voltage: 3---5V.
- Protect-----This strong heavy duty tool bag can protect your tools from water and dust.
- 【Scope of Application】- The product can be applied to various RF receiving front ends, used for shortwave, FM broadcasting, remote control receivers, cable TV signal amplifiers and other RF signal amplifications that require low noise.
- 【Excellent Performance】-The radio frequency amplifier is made of high-quality electronic components and has the advantages of high gain, low noise figure, etc.
- 【Low Noise】- The noise factor is as low and 0.55dB, which is quite small.
Check StockKETOTEK Digital AC Voltmeter Panel Mounting Meter AC80-300V Frequency Counter 45.0-65.0 HZ LED Display Voltage Volt Frequency Meter Tester Gauge
- 【2 in 1 Multimeter】Voltage and frequency can be displayed with different color on the LED screen, red for voltage, green for frequency. It is clear and convenient to read..
- 【Wide measuring range】Voltage: AC 80~300V, Hertz: 45-65Hz, Accuracy: 1% ± 2 digits, with high working efficiency of 2 times/s measuring speed..
- 【No extra individual power supply】It can directly connect two wires to the tested voltage to measure voltage and frequency without power supply..
- 【Ultra small size】2.68×1.65×1.5inch / 68x42x38mm. This Voltage Frequency Meter can be installed on anywhere flexibly..
- 【More information】Operating temperature: 10°F~122°F/-10℃ ~ 50℃. Note: The AC current meter only suits for pure AC 50-60HZ power supply and can NOT be used for square wave, inverter output and sine wave circuit measurement of modified sine wave, otherwise the meter will be damaged..
Check StockSWM
- Technical Information - Frequency Range - 2000 kHz to 2150 MHz.
- Input Voltage Range - 100 V AC to 120 V AC.
Check StockDual Band Radio, Selectable Narrow Broadband VHF 136174 MHZ UHF 400520 MHz PTT ID Wireless Walkie Talkie Function Aviation 108136 MHz for Adults US Plug
- Portable Design: The walkie talkie is small and light, gray body, simple and atmospheric, suitable for adults, can be used in various restaurants, shopping malls, security and other ..
- Dual PTT: PTT 1 transmits the A segment frequency, and PTT 2 transmits the B segment frequency. Narrowband broadband selectable..
- Multi Information Display: With a 1.4 inch screen, it can clearly display the channel number, frequency, channel frequency, channel name, etc..
- Multifunctional: Battery voltage display, keypad lock and unlock, dual frequency, voice delay, FM radio, scan, PTT ID function..
- Frequency Range: UHF 400‑520MHz, VHF 136‑174MHZ, aviation frequency band 108‑136MHz. 10W 5W high and low power settings..
Check StockKeeptop Non-Contact Voltage Tester - Electrical Tester with Dual Range AC 12 to 1000V, Live/Null Wire and Circuit Tester, Voltage Detector with Flashlight and Pocket Clip
- Super Large LCD Screen -- Compared with other voltage testers, our screen is 6.6 larger than their testers, and the high resolution screen will show 3 test results, such as the volt, frequency and analog bar.
- Non-Contact & 8 LED Indicators -- Non contact voltage detection ensures the safety of testing, and 8 LED Indicators in 3 colors display (Green, Yellow, Red) help to distinguish the detected voltage intensity easily.
- Auto-ranging Digital Multimeter -- Designed for the novice. Plug the test leads only, the multimeter tester can smart to test voltage DC or AC frequency, resistance, as well as continuity.
- Perfect Helper for Electrical Issues -- SUETTLA X1 Volatge tester arrive CAT II 600V safety level, help to detect the null/live wire, breakpoint locate, AC/DC volts testing, Ohm measure etc, to save the high service fees..
- Fastest Reading Speed -- With upgraded chips, greatly increase the sensitivity, make the voltage multimeter tester measuring in 0.2s (5 times/s).
Check StockPRINCE CASTLE Drive Motor Assembly 87-028AS
- ATO 110v vfd, single phase 110v/120v input, single phase or three phase 220v output, achieve to run 220v AC motor on single phase 110v/120v power supply.
- 【Voltage& Frequency】Input voltage: 1 phase 120V AC ±15%, Input frequency: 50Hz/60Hz,Output voltage: 1 phase or 3 phase 220V AC ±15%, Output frequency: 0.00~400.00Hz.
- 【APPLICATION】ATO 7.5 hp 5.5kW variable frequency drive Can be widely applied to drive the AC motor, such as fans, pumps, power tools, etc.
- 【TIPS】 To protect the variable frequency drive and Motor, you need an upstream protection, add a line-choke upstream the VFD, this will reduce the current transients seen by the input of the VFD.
- 【CUSTOMER FIRST】If you have no experience in driving a VFD, be sure to refer to the instructions before operating a VFD.If you are not sure about the size or have any issue about the product or service, please don't hesitate to email us. We will answer you within 12h.
Check StockLoulensy 3-Phase AC Voltage Transducer Sensor Transformer Transmitter 3-Input 0-300V AC with 3-Output 0-5V DC
- Capacity Max:0-500V AC (Customerized,contact operator if you need other input ranges,e.g.0-75mV or 0-300V).
- Impulse Voltage:5KV(peak value),1.2/50uS.
- Default Frequency:40-60Hz(contact us,if you specially need different frequency,e.g. 100Hz).
- Load Capacity: 2 times current continuous.
- Isolation Withstanding Voltage:AC 2.0KV/min*1mA between input/output/power.
- Feature:Voltage Terminal Insert,standard din rail(35mm)mounting or pannel mounting.
- Storage Temperature:-40 to 70 degrees Centigrade,20% to 95% without condensation.
- Working Stability: annual change 003c 0.2%.
- Working Environment:-10 to 50 degrees Centigrade,20% to 90% without condensation.
- Isolation Resistance:003e/=20M Ohm(DC513V).
Check StockLoulensy 3-Phase AC Voltage Transducer Sensor Transformer Transmitter 3-Input 0-450V AC with 3-Output 4-20mA DC
- Capacity Max:0-500V AC (Customerized,contact operator if you need other input ranges,e.g.0-75mV or 0-300V).
- Impulse Voltage:5KV(peak value),1.2/50uS.
- Default Frequency:40-60Hz(contact us,if you specially need different frequency,e.g. 100Hz).
- Load Capacity: 2 times current continuous.
- Isolation Withstanding Voltage:AC 2.0KV/min*1mA between input/output/power.
- Feature:Voltage Terminal Insert,standard din rail(35mm)mounting or pannel mounting.
- Storage Temperature:-40 to 70 degrees Centigrade,20% to 95% without condensation.
- Working Stability: annual change 003c 0.2%.
- Working Environment:-10 to 50 degrees Centigrade,20% to 90% without condensation.
- Isolation Resistance:003e/=20M Ohm(DC520V).