Reviews Motor Contactor
12V 250A Winch Solenoid Relay Contactor Thumb Truck for ATV UTV 2000-5000lbs Winch with 6 Protecting Caps - Ovsor
- 【PRODUCT PARAMETER】- Voltage - 12V, power – 250A, capacity - 2000-5000lbs, for ATV Winch Solenoid Relay Contactor Switch 12V 250 AMP 1500lb-5000lb Application..
- 【HIGH QUALITY】 - Made of strong, weather-resistant steel and powder-coated black surface, with super durability. OEM of high quality KFI winch kit is a great alternative to replace contactor..
- 【MULTIFUNCTIONAL APPLICATION】- For ATV Winch Solenoid Relay Contactor Switch 12V 250 AMP 1500lb-5000lb Application. Direct Replacement for UTV ATV Winch Solenoid Relay Contactor Switch 12V 250 AMP..
- 【INSTALLATION GUIDE】- Easy to install. The two wires - Green and Black which go to the switch that controls In and Out on a winch. Blue and yellow go to motor, Black and red go to battery..
- 【AFTER-SALES SERVICE】- If the product fails or other problems, you can contact us at any time, we will solve the problem for you within 12 hours..
Check StockElectrodepot 40 Amp 12 Pole (4 Pole x 3) Normally Open, 110-120VAC Coil (Silent Operation), Motor Load 40A and Lighting Load 63A Contactor Bundle with 8\ DIN Rail and 2 Number 10 Screws
- BUNDLE CONTENT: 6 ITEMS – Three (3) 40A 4 Pole Normally Open (NO) Contactors with power status indicator.
- one (1) compatible Slotted Steel Zinc Plated 35mm x 200mm DIN Rail and two (2) stainless steel truss head screws (#10, 1/2") for immediate home or industrial installation.
- CONTACTOR APPLICATIONS – Lighting, motor or switching. AC-1 for resistance furnaces, incandescent lamps or electric heaters.
- and AC-3 for air conditioners, compressors or fans. 24/120/220/277 V, with an energy saving, silent and no humming coil.
- COIL VOLTAGE AND LOAD – Contactor IEC 400V. Coil Voltage 110/120VAC, 50/60 Hz.
- Coil load Inrush 52VA, Sealed 10VA. Inductive/Motor Load: 40Amp, Resistive/Incandescent Load: 63Amp. DC Load: 30Amp @ 24VDC. Compatible with 15 Amp, 20 Amp, 30 Amp, 32 Amp, 40 Amp, 50 Amp, 60 Amp and 63 Amp loads. Power Lug Terminal Capacity AWG # 4.
- OTHER CONTACTOR DETAILS – Contactor type NO with 4 poles, power status indicator. IEC AC Rate: AC-1.
- 8 kW. Electric e strength: 4 kV. Operating Temperature -30…+70 °C (-22…+158 °F). Dimensions (approx.): 54 x 64 x 84 mm / 2.1'' x 2.5'' x 3.3'' (Length x Width x Height).
- DIN RAIL – Standard mounting support for any electromechanical component, including contactors, using the DIN specificat....
Check StockElectrodepot 40 Amp 8 Pole (4 Pole x 2) Normally Open, 110/120VAC Coil (Silent Operation), Motor Load 40A and Lighting Load 63A Contactor Bundle with DIN Rail, 35 x 150 mm and 2#10 Screws
- BUNDLE CONTENT: 5 ITEMS – Two (2) 40A 4 Pole Normally Open (NO) Contactors with power status indicator.
- one (1) compatible Slotted Steel Zinc Plated 35mm x 150mm DIN Rail and two (2) stainless steel truss head screws (#10, 1/2") for immediate home or industrial installation.
- CONTACTOR APPLICATIONS – Lighting, motor or switching. AC-1 for resistance furnaces, incandescent lamps or electric heaters.
- and AC-3 for air conditioners, compressors or fans. 24/120/220/277 V, with an energy saving, silent and no humming coil.
- COIL VOLTAGE AND LOAD – Contactor IEC 400V. Coil Voltage 110/120VAC, 50/60 Hz.
- Coil load Inrush 52VA, Sealed 10VA. Inductive/Motor Load: 40Amp, Resistive/Incandescent Load: 63Amp. DC Load: 30Amp @ 24VDC. Compatible with 15 Amp, 20 Amp, 30 Amp, 32 Amp, 40 Amp, 50 Amp, 60 Amp and 63 Amp loads. Power Lug Terminal Capacity AWG # 4.
- OTHER CONTACTOR DETAILS – Contactor type NO with 4 poles, power status indicator. IEC AC Rate: AC-1.
- 8 kW. Electric e strength: 4 kV. Operating Temperature -30…+70 °C (-22…+158 °F). Dimensions (approx.): 54 x 64 x 84 mm / 2.1'' x 2.5'' x 3.3'' (Length x Width x Height).
- DIN RAIL – Standard mounting support for any electromechanical component, including contactors, using the DIN specificatio....
Check StockCarrier HVAC Motor Contactor, 120V 30 Amp Coil 2 Pole Replacement Relays Compatible with C230B, Air Conditioner, Heat Pump, Refrigeration Systems
- 【Carrier HVAC contactor】120 VAC, 50/ 60 Hz, amperage (FLA): 30 A, resistive (RES): 40 A, compatible devices up to 600 VAC.
- 【Certified Replacement relays】stable and durable, compact design to protect the contactor from dust and other environmental elements.
- 【Industrial workmanship】equipped with binding head screws, includes lug, covers and quick connect spade terminals, coils features insulation, coil is encapsulated with no exposed tape wrapping.
- 【Wide application】great switch solution for HVAC, elevators, pools, food processing, pumps or compressors, lighting, hoists and cranes, battery chargers, printing presses, vending machines, and agriculture, compatible with C230B/ TJT30A120V2P/ 17325/ PC230A/ H230A/ 90-244.
- 【Practical tool】quality home and industrial facility should be available to everyone, you'll get 1 piece 2 pole motor contactor.
- If you can't find the model you are looking for, please contact us for assistance.
Check StockMigro 1 Pole 40 AMP Heavy Duty AC Contactor Replaces Virtually All Residential 1 Pole Models C140A Equivalent 5- Year Warranty Upgraded Increased Silver Alloy Content up to 27% AgCdO12
- 【Carrier Hvac Contactor】24VAC, 50/60Hz, amperage (FLA): 40A, resistive (RES): 50A, compatible devices up to 600 VAC.
- 【UL Certified Replacement Relays】Stable and durable, compact design to protect the contactor from dust and other environmental elements.
- 【Industrial Workmanship】Equipped with binding head screws, includes lug, covers and quick connect spade terminals, coils features class b....
- 【Wide Application】Great switch solution for HVAC, elevators, pools, food processing, pumps or compressors, lighting, hoists and cranes, battery....
- 【Why You Choose Us】High quality home and industrial facility should be available to everyone, you'll get 1 x 1 pole motor contactor.
Check StockSIEMENS 6ES7 214-1AG40-0xB0 SIMATIC S7-1200 CPU 1214C, Compact CPU
- ..., can achieve thousands of functions, stable and reliable working performance, built-in watchdog timer circuit, to ensure that the module for a long time to run Input high speed pulse C235, C251 and FX1N compatible.Output relay 1A output, Rated current 5A, can directly drive DC solenoid valve, AC solenoid valve, AC contactor, AC motor, etc..
- Programmable Control -- This module is programmable control, can achieve thousands of functions, stable and reliable working performance, built-in watchdog timer circuit, to ensure that the module for a long time to run Input high speed pulse C235, C251 and FX1N compatible.Output relay 1A output, Rated current 5A, can directly drive DC solenoid valve, AC solenoid valve, AC contactor, AC motor, etc..
- Built-in Analog Input and Output -- Built-in Analog input AD, corresponding to internal data register D5030.(Not D8030) Built-in Analog output DA, corresponding to internal data register D5101..
- The PLC with Two Programming Port -- The TTL interface and the 232 interface. The 232 interface, you can directly use the USB-232 serial port with a computer to download the program directly. When the PLC need to connect with the touch screen or text, can be used to connect 232 programming port..
Check StockElectrodepot 30 Amp 3 Pole Contactor, 110-120V Coil, Motor Load 32A, Lighting 40A, 50A Bundle with Slotted Steel Zinc Plated DIN Rail, 35 Millimeters x 6 Inches – 1 Piece with 2 Number 10 Screws
- BUNDLE CONTENT: The bundle includes one (1) 30A Contactor and one (1) compatible Slotted Steel Zinc Plated DIN Rail with two (2) drive stainless steel truss head screws (#10, 1/2") for immediate installation.
- LOAD: Inductive/Motor Load, 32Amp. Incandescent/General purpose Load, 50Amp. Lightning, 40Amp, 50Amp.
- COIL RATED VOLTAGE: AC 110V/120V, 50/60Hz.
- AUXILIARY CONTACTS: 1 NC (Normally Closed) and 1 NO (Normally Open) incorporated contacts.
- CONTACTOR DIMENSIONS (approx.): 85 x 45 x 92 mm / 3.4'' x 1.7'' x 3.6'' (Length x Width x Height).
Check StockTrane • 40 Amp 1 Pole 24v Coil Packard Replacement Contactor C140A
- 200K cycles UL testing approval for Dp contactor.
- Replace SIEMENS 45 series dp contactor 1 pole 40FLA 24V coil.
- UL,CUL CSA, SEV S+, CE Approved AC contactor.All our DP contactors series meet the ARI Standard 780/790-1997 and UL508 standard.
- Replacement parts number: 8910DP41V14, 3100-15Q19, C25ANF140T, 45GG10AJA,HCCY1XQ04GG, C140A, DP40241..
Check StockWEG BCXML11 Motor Contactor
- WEG manufacturers motors, controls, coatings and more for power distribution and automation.
Check StockEZGO Golf Cart 25864G09 Electronic Speed Controller
- Shunt wound controller designed to fit E-Z-Go PDS.
- Regenerative braking and contactor-less motor reversing.
- Separate armature and field current limits.
Check Stock