Reviews Differential Temperature Thermocouple

GBC Document Camera, Discovery 3000 (DCV10004)

  • pyrometer Temperature range: -50°C to 1300°C ( -58°F to 2372°F) and Overload display alert when input exceeds measurement range pyrometer. Thermocouple Temperature range: -50°C to 1000°C ( -58°F to 1832°F).
  • Designed for use with K-type thermocouples and Selection between Celsius and Fahrenheit.
  • Decimal or round number display selectable (decimal range is -58.0F to999.9F and round number range is -58F to 2372F).
  • Includes 2 Thermocouples ( One 3" K type temperature probe (-58 – 752 °F) and one Kiln Heavy duty K type Thermocouple ( -58°F to 1832°F) and Digital Pyrometer, 9V battery and Manual.
  • Thermocouple Measurement range: 32 - 1832 °F (0 - 1000 °C) Thermocouple Type: K Type Cable length : 3 ft Sensing tip length: 6" (150mm) Stainless Steel Sensing tip diameter: 0.19" (5mm) Thread width : 5/16" (M8) Internal Insulation: Fiber Glass External shielding: Metal Shield (Stainless steel braided).
Check Stock

Extech SDL200 Four-Channel Thermometer SD Logger

  • 4 Channel datalogging with 6 Thermocouple types (J, K, E, T, R,S).
  • 2 Channel datalogging with RTD (Pt100Ohm) probes.
  • Displays [T1, T2, T3, T4] or differential [T1 , T2] reading.
  • Datalogger date/time stamps and stores readings on an SD card in Excel format for easy transfer to a PC.
  • Offset adjustment used for zero function to make relative measurements.
Check Stock

Infrared Thermometer SOVARCATE Digital IR Laser Thermometer Temperature Gun High and Low Temperature Alarm -58°F~1112°F / -50℃~600℃ Temperature Probe for Cooking/BBQ/Food/Fridge/Pizza Oven/Engine

  • [AUTO OFF FUNCTION] You can save the battery energy by its automatic power off function after 10min of no measurement. On the other hand, user can also select to disable the auto power off function as needed during the measurement procedure..
  • [TEMPERATURE DIFFERENTIAL MEASUREMENT T1-T2] This thermometer not only features with Data Hold, Max/Min/Avg measurement function, but also "T1-T2 / T2-T1" calculation function. Just simply long press the T1-T / T2-T1 key to display the difference in temperature between probe 1 and probe 2..
Check Stock

ennoLogic Volt mA Thermocouple Loop Process Calibrator eC370T - 0-20V and 4-20mA Simulator – Portable Millivolt mA and Temperature Signal Generator and Meter for Transmitters Current Loops PLC

  • VERSATILE AND ACCURATE VOLT MA THERMOCOUPLE CALIBRATOR: Signal generator, simulator and volt / mA meter for calibrating, testing and repairing milliamp loops, thermocouples, PLC, temperature control and HVAC systems. Easily generate precise test signals for current and voltage devices (mA, mV, V, Celsius and Fahrenheit ranges)..
  • NUMERIC KEYPAD for ease and flexibility in setting output signals configuring options. HOTKEY programming for each numeric key (long-press immediately outputs user-configured voltage, current or temperature signal). RAMP AND LADDER OUTPUT FUNCTIONS can be custom configured. BUILT-IN 24V LOOP SUPPLY lets you power and read a device or transmitter without needing another multimeter. This greatly simplifies testing 2-wire current loops..
  • MEASURE VOLTAGE OUTPUT SIGNALS from process devices and sensors with two input ranges of 0-100mV (0.01mV resolution, 0.06% accuracy) and 0-20V (1mV resolution, 0.08% accuracy). MEASURE CURRENT TRANSMITTERS within a range of 0 to 24mA with 0.001mA resolution and 0.08% accuracy. MEASURE THERMOCOUPLE TEMPERATURES within a range of -250°C to +1800°C and resolution of ±0.7°C to ±2°C (range and resolution depends on thermocouple type, supported are type K, J, E, T, N, S, R, and B.).
Check Stock

Cooper-Atkins 93230-K Thermocouple Thermometer (Thermocouple K Type Thermometer) - EconoTemp Combo Pack

  • Thermocouple K Type Thermometer - Includes 32311 thermocouple thermometer, wall bracket, and DuraNeedle probe 50336-K. For foodservice and general purpose temperature monitoring..
  • Accurate Thermocouple Thermometer - Temperature range from -40 to 500 degrees Fahrenheit, precise to +/- 2 degrees Fahrenheit across entire range..
  • DuraNeedle 2 Second Response Time - Includes DuraNeedle 50336-K probe with ultra-fast response time. Features easy to read digital display and 10 minute auto shutoff..
  • Cooper-Atkins Corporation - Headquartered in Middlefield, CT, Cooper-Atkins has been a leading manufacturer of quality time, temperature, and humidity instruments serving the Foodservice, HVAC and Healthcare markets since 1885..
Check Stock

Digital pyrometer F,C pottery ceramic glass kiln Sensor Thermometer Thermocouple

  • Digital Pyrometer Temperature range: -50°C to 1300°C ( -58°F to 2372°F).
  • Ceramic thermocouple Temperature range: -50°C to 1300°C ( -58°F to 2372°F).
  • Included Pyrometer and 2 type K thermocouple ( One 3" K type thermocouple(-50 to 400°C) and one Kiln K type (-50 to 1300°C)).
  • Decimal or round number display selectable (decimal range is -58.0F to999.9F and round number range is -58F to 2372F).
  • Shipping to USA is 3-6 business days. For more information please go to our website Thermomart.
Check Stock

2 Pcs Digital 2 Channels K Type Thermometer with 8 Thermocouples (Wire and Stainless Steel) -50~1300°c (-58~2372°f) Dual Measurement Meter Sensor Handheld HVAC Thermometer High Temperature Pyrometer

  • High Accuracy: reading accuracy (±0.1°C ±0.4), fast response using K type thermocouple probe, this digital temperature gauge will bring you a lot of convenience.
  • You will get 2 pcs of K type thermometers, 4 pcs of wire thermocouples and stainless steel thermocouples.
  • Multiple Temperature Display: in addition to the max/ min/ average, data hold, and auto power off functions, this hand held temperature reader is specially designed with a "T1-T2" calculation function, making it easy for the user to find the difference between two samples.
  • ​Portable and Practical: powered by battery, this thermometer with probe is portable and practical, operate it with 6 simple buttons with clear instructions, suitable for beginners and skilled users.
  • Plus, the removable silicone rubber cover protects your device from accidental drops.
  • It is factory calibrated and factory reset, and any standard K type thermocouple connector can be applied to replace the included thermocouple when needed.
  • Wide Measurement Temperature Range: mainframe range of digital k type thermometer is about -50°C ~ 1300°C (-58°F ~ 2372°F).
Check Stock

CNAODUN PID Temperature Controller Kit 100-240 VAC Voltage with 40DA Solid State Relay,K Type Thermocouple Probe and Heat Sink

  • ♥【One Way SSR output】3,4 port output to SSR,a 40da solid state relay is included in the package.The power supply voltage for this Pid temperature controller is 100-240VAC..
  • ♥【One Alarm Output】6,7 ports are alarm outputs, AC220V/DC30V 3A (Resistive load) ON/NC, also can be used to connect relay..
  • ♥【Supports 2 Wire Sensor Input】Support two-wire thermocouple input, K, E, J, N, W3-25, W5-26 type thermocouple input are available, the default setting is K type thermocouple input.
  • ♥【℉ and ℃ Adjustable】Fahrenheit and Celsius adjustable, default is Fahrenheit, with PID function.
  • ♥【Temperature Digital Display】PV is the current measured temperature, SV is the set temperature, both are displayed simultaneously..
Check Stock

Instrukart Dry Block High Temperature Calibrator AI-DBC 650 for Calibration Labs Pharmaceutical divisions Thermal Plants divisions Along with Calibration Certificate

  • Accuracy: ±0.6°C, Bath Stability: ±0.5°C.
  • Measuring Functions: J Type Thermocouple, K Type Thermocouple, T Type Thermocouple, R Type Thermocouple, S Type Thermocouple, N Type Thermocouple, MA, MV, Volts, Ohms, RTD (Pt 100).
  • Temperature Steps: 50°C, 150°C, 300°C, 450°C, 600°C.
  • Switch Test: Continuity check with OPEN / CLOSE indication.
  • Transmitter Supply: 24V DC ± 10% (Loop Powered).
  • Power Supply: 230V AC ± 5% / 50Hz, 500 W for 350UTC.
  • Supply Scope: Instrument, Power Cable, Carrying Case, Test Lead(2 & 3 Wire), Insertion Tube, Insertion Tool,Spare Fuses: 6A x 2nos User Manual, Calibration Certificate.
Check Stock

Amprobe TMD-50 Thermocouple Thermometer K-type

  • Portable, dual-input thermometer for reading temperatures from two sources simultaneously, and is used in quality control and HVAC, electrical, industrial, and automotive maintenance.
  • Dual-scale temperature readings range from -328 to 2,498 degrees F (-200 to 1,370 degrees C).
  • Dual-input thermocouples for superheat and subcool applications, and cut-out and cut-in temperature measurements, and offset mode compensates for thermocouple error.
  • Backlit LCD screen with a data hold feature to save temperature readings for later viewing, maximum and minimum temperature with elapsed time, average and relative temperature calculations, and low battery indicator.
Check Stock