Reviews Defrost Thermostat
Jovitec Refrigerator Defrost Replacements WR51X10055 Defrost Heater WR55X10025 Temperature Sensor WR50x10068 Defrost Thermostat Compatible with GE
- You will receive: 1 x refrigerator defrost heater WR51X10055, 1 x refrigerator temperature sensor WR55X10025, 1 x refrigerator defrost thermostat....
- WR51X10055 defrost heater: it can replace for No. WR51X10030, AP3183311, PS303781, 914088, AH303781, EA303781, PS303781, WR51X10030.
- WR55X10025 temperature sensor: it can replace for No. 914093, AP3185407, WR50x10027, WR50x10034, WR50x10055, WR50x10067, WR55X10025, WR55X10026,....
- WR50x10068 defrost thermostat: it can replace for No. PS1017716, 1170024, AP3884317, WR50x10015, WR50x10017, WR50x10018, WR50x10028, WR50x10051,....
- General replacement: refrigerator replacement parts made of durable material that ensures a long life using, compatible with refrigerator of GE,....
Check StockAntoble Refrigerator Defrost Heater WR51X10101 WR51X10053 Replacement for GE General Electric, Hotpoint, RCA
- Compatible with WR51X10101 AP4355467 1399613 AH1993872 EA1993872 PS1993872 WR51X10032 WR51X10053 WR51X10097.
- There are three main parts to a refrigerator automatic defrost: defrost timer, defrost heater and defrost thermostat.
- All three of these parts work together to ensure ice buildup doesn't occur inside and outside your refrigerator and freezer.
Check StockDixell XR60CX-5N1C1 Digital Thermostat Controller with Defrost Compressor Control of Evaporator Fans 230V/50-60Hz Programmable-Commercial for Refrigeration
- The regulation is performed according to the temperature measured by the thermostat probe with a positive differential from the set point: if the temperature increases and reaches set point plus differential the compressor is started and then turned off when the temperature reaches the set point value again.In case of fault in the thermostat probe the start and stop of the compressor are timed through parameters COn and COF..
- Two defrost modes are available through the tdF parameter:defrost through electrical heater (tdF= EL) and hot gas defrost (tdF = in).Other parameters are used to control the interval between defrost cycles (IdF), its maximum length (MdF) and two defrost modes: timed or controlled by the evaporator?s probe (P2P).At the end of defrost dripping time is started, its length is set in the FSt parameter. With FSt =0 the dripping time is disabled..
- Forced activation of fans This function managed by the Fct parameter is designed to avoid short cycles of fans, that could happen when the controller is switched on or after a defrost, when the room air warms the evaporator. Functioning: if the difference of temperature between the evaporator and the room probes is more than the value of the Fct parameter, the fans are switched on. With Fct=0 t....
Check Stockuxcell a12080600ux0947 Bimetal Temperature Control Switch Thermostat (Pack of 10)
- It is a digital thermostat with off cycle defrost designed for refrigeration applications at normal temperature.It provides two relay outputs, one for the compressor,the other one can be used as light, for alarm signalling or as auxiliary output..
- The regulation is performed according to the temperature measured by the thermostat probe with a positive differential from the set point: if the temperature increases and reaches set point plus differential the compressor is started and then turned off when the temperature reaches the set point value again. In case of fault in the thermostat probe the start and stop of the compressor are timed through parameters COn and COF..
- Defrost is performed through a simple stop of the compressor. Parameter ?IdF? controls the interval between defrost cycles, while its length is controlled by parameter MdF.Case,XR30CX frontal 32x74 mm.
- SAFETY PRECAUTIONS Check the supply voltage is correct before connecting the instrument. Do not expose to water or moisture: use the controller only within the operating limits avoiding sudden temperature changes with high atmospheric humidity to prevent formation of condensation. Warning: disconnect all electrical connections before any kind of maintenance. Fit the probe wher....
Check StockW10225581 Refrigerator Bimetal Defrost Thermostat for Whirlpool KitchenAid Kenmore Replace WPW10225581 AP6017375 PS11750673 PS237680,2321799
- W10225581 Refrigerator Bimetal Defrost Thermostat for Whirlpool KitchenAid Kenmore Replace WPW10225581, AP6017375, PS11750673, PS237680,2321799.
- Replacement Bimetal Defrost Thermostat used on For some Amana, Crosley, Estate, Ikea, Inglis, Jenn Air, Kenmore, KitchenAid, Magic Chef, Maytag, Roper....
- replaces part number: WPW10225581, WPW10225581V ,W10225581, W10260437,AP4511066, 2321799, 2321802, 2319914, 2188824, 2315504, 1872722, 2149849,....
- Suitable for the following situations: Fridge too warm,Freezer section too warm,Frost buildup,Fridge and freezer are too warm,Too warm ,Freezer not....
Check StockDixell XR40CX-5N1C1 230V/50Hz-60Hz Digital Thermostat Controller with Defrost Management Programmable-Commercial for Refrigeration Units
- Suitable for appliances including:for applications on medium or low temperature refrigerating units.XR40CX-5N1C1 230V/50-60Hz..
- The regulation is performed according to the temperature measured by the thermostat probe with a positive differential from the set point:if the temperature increases and reaches set point plus differential the compressor is started and then turned off when the temperature reaches the set point value again. In case of fault in the thermostat probe the start and stop of the compressor are timed through parameters COn and COF..
- Two defrost modes are available through the tdF parameter: defrost through electrical heater (tdF= EL) and hot gas defrost (tdF = in). Other parameters are used to control the interval between defrost cycles (IdF), its maximum length (MdF) and two defrost modes: timed or controlled by the evaporator?s probe (P2P).At the end of defrost dripping time is started, its length is set in the FSt parameter. With FSt =0 the dripping time is disabled..
- SAFETY PRECAUTIONS Check the supply voltage is correct before connecting the instrument. Do not expose to water or moisture: use the controller only within the operating limits avoiding sudden temperature changes with high atmospheric humidity to prevent formation of ....
Check StockUltra Durable WR50x10065 Refrigerator Defrost Thermostat by BlueStars - Compatible with GE Refrigerators - Replaces AP3796816
- ✅MODEL NUMBER: WR50x10065 refrigerator defrost thermostat..
- ✅EASY TO INSTALL: Easy installation and ideal DIY solution to make your refrigerator function properly..
- ✅HIGH COMPATIBILITY: This grease filter works perfectly on various GE and Hotpoint refrigerators and replaces AP3796816..
- ✅PREMIUM QUALITY: The WR50x10065 defrost thermostat is manufactured from high-grade & durable materials to ensure great performance on your....
- ✅MONEY-BACK GUARANTEE: Feel free to contact us whenever you raise a question. All products of BlueStars come with a guarantee against major defects,....
Check StockHoneywell Mini Compact Freezer Countertop, 1.1 Cubic Feet, Single Door Upright Freezer with Reversible Door, Removable Shelves, for Home, Dorms, Apartment, Office- Stainless Steel
- TEMPERATURE: There is an adjustable thermostat to choose the desired temperature. Adjustable thermostat.
- MANUAL DEFROST: The freezer is manual defrost..
- REVERSIBLE DOOR: The door is reversible and can swing either way you choose. ADJUSTABLE FEET: The feet can be adjusted to perfectly lever the freezer.
- COMPACT: The dimensions are 17.7x19.4x20.4 inches..
Check StockDixell XR20CX-5N1C1 230V/50-60Hz Digital Thermostat Controller Off Cycle Compressor Defrost Programmable-Commercial for Refrigeration
- It is a digital thermostat with off cycle defrost designed for refrigeration applications at normal temperature.It provides a relay output to drive the compressor.Suitable for appliances including:for refrigeration applications at normal temperature..
- COMPRESSOR:The regulation is performed according to the temperature measured by the thermostat probe with a positive differential from the set point: if the temperature increases and reaches set point plus differential the compressor is started and then turned off when the temperature reaches the set point value again. In case of fault in the thermostat probe the start and stop of the compressor are timed through parameters COn and COF..
- Defrost is performed through a simple stop of the compressor. Parameter ?IdF? controls the interval between defrost cycles, while its length is controlled by parameter MdF..
- SAFETY PRECAUTIONS Check the supply voltage is correct before connecting the instrument. Do not expose to water or moisture: use the controller only within the operating limits avoiding sudden temperature changes with high atmospheric humidity to prevent formation of condensation. Warning: disconnect all electrical connections before any kind of maintenance. Fit the probe where it is not accessibl....
Check StockDanby 3.5 Cubic Feet Chest Freezer with Energy Efficient Foam Insulated Cabinet for Extra Food Storage
- 3.5 CUBIC FEET: 3.5 cubic feet (98 L) capacity chest freezer.
- ECO-FRIENDLY: Environmentally friendly R600a refrigerant.
- MANUAL DEFROST: Manual defrost with front mount defrost drain.
- INDICATOR LIGHT: Front mount mechanical thermostat with “power-on” indicator light.
- ENERGY EFFICIENT: Energy efficient foam insulated cabinet & lid.
Check Stock