Reviews Air Conditioning Contactor
Electrodepot 40 Amp 4 Pole Normally Closed Contactor, 110-120V Coil, Motor Load 20A, Lighting 40A Bundle with Slotted Steel Zinc Plated DIN Rail, 35 mm x 6 in – 1 Piece with 2 Number 10 Screws
- BUNDLE CONTENT: 4 ITEMS – One (1) 40A Contactor, one (1) compatible Slotted Steel Zinc Plated DIN Rail and two (2) drive stainless steel truss head screws (#10, 1/2") for immediate installation.
- APPLICATIONS – Lighting, motor or switching. AC-1 for resistance furnaces, incandescent lamps or electric heaters.
- and AC-3 for air conditioners, compressors or fans. 24/120/220/277 V, with an energy saving, silent and no humming coil.
- COIL VOLTAGE AND LOAD – Contactor IEC 400V. Coil Voltage 110/120VAC, 50/60 Hz.
- Coil load Inrush 30VA, Sealed 4VA. Inductive/Motor Load: 20Amp, Resistive/Incandescent Load: 40Amp. DC Load: 30Amp @ 24VDC. Compatible with 20 Amp, 30 Amp, 32 Amp and 40 Amp loads. Power Lug Terminal Capacity AWG # 4.
- OTHER CONTACTOR DETAILS – Contactor type NC with 4 poles, power status indicator. IEC AC Rate: AC-1.
- 8 kW. Electric e strength: 4 kV. Operating Temperature -30…+70 °C (-22…+158 °F). Dimensions (approx.): 85 x 45 x 92 mm / 3.4'' x 1.7'' x 3.6'' (Length x Width x Height).
- DIN RAIL – Standard mounting support for any electromechanical component, including contactors, using the DIN specifications adopted by European (EN) and international (IEC) standards. Standard width 34.9mm (1.375”) length 152.40mm (6”) and t....
Check StockElectrodepot 40 Amp 12 Pole (4 Pole x 3) Normally Open, 110-120VAC Coil (Silent Operation), Motor Load 40A and Lighting Load 63A Contactor Bundle with 8\ DIN Rail and 2 Number 10 Screws
- BUNDLE CONTENT: 6 ITEMS – Three (3) 40A 4 Pole Normally Open (NO) Contactors with power status indicator.
- one (1) compatible Slotted Steel Zinc Plated 35mm x 200mm DIN Rail and two (2) stainless steel truss head screws (#10, 1/2") for immediate home or industrial installation.
- CONTACTOR APPLICATIONS – Lighting, motor or switching. AC-1 for resistance furnaces, incandescent lamps or electric heaters.
- and AC-3 for air conditioners, compressors or fans. 24/120/220/277 V, with an energy saving, silent and no humming coil.
- COIL VOLTAGE AND LOAD – Contactor IEC 400V. Coil Voltage 110/120VAC, 50/60 Hz.
- Coil load Inrush 52VA, Sealed 10VA. Inductive/Motor Load: 40Amp, Resistive/Incandescent Load: 63Amp. DC Load: 30Amp @ 24VDC. Compatible with 15 Amp, 20 Amp, 30 Amp, 32 Amp, 40 Amp, 50 Amp, 60 Amp and 63 Amp loads. Power Lug Terminal Capacity AWG # 4.
- OTHER CONTACTOR DETAILS – Contactor type NO with 4 poles, power status indicator. IEC AC Rate: AC-1.
- 8 kW. Electric e strength: 4 kV. Operating Temperature -30…+70 °C (-22…+158 °F). Dimensions (approx.): 54 x 64 x 84 mm / 2.1'' x 2.5'' x 3.3'' (Length x Width x Height).
- DIN RAIL – Standard mounting support for any electromechanical component, including contactors, using the DIN specificat....
Check StockElectrodepot 40 Amp 8 Pole (4 Pole x 2) Normally Open, 110/120VAC Coil (Silent Operation), Motor Load 40A and Lighting Load 63A Contactor Bundle with DIN Rail, 35 x 150 mm and 2#10 Screws
- BUNDLE CONTENT: 5 ITEMS – Two (2) 40A 4 Pole Normally Open (NO) Contactors with power status indicator.
- one (1) compatible Slotted Steel Zinc Plated 35mm x 150mm DIN Rail and two (2) stainless steel truss head screws (#10, 1/2") for immediate home or industrial installation.
- CONTACTOR APPLICATIONS – Lighting, motor or switching. AC-1 for resistance furnaces, incandescent lamps or electric heaters.
- and AC-3 for air conditioners, compressors or fans. 24/120/220/277 V, with an energy saving, silent and no humming coil.
- COIL VOLTAGE AND LOAD – Contactor IEC 400V. Coil Voltage 110/120VAC, 50/60 Hz.
- Coil load Inrush 52VA, Sealed 10VA. Inductive/Motor Load: 40Amp, Resistive/Incandescent Load: 63Amp. DC Load: 30Amp @ 24VDC. Compatible with 15 Amp, 20 Amp, 30 Amp, 32 Amp, 40 Amp, 50 Amp, 60 Amp and 63 Amp loads. Power Lug Terminal Capacity AWG # 4.
- OTHER CONTACTOR DETAILS – Contactor type NO with 4 poles, power status indicator. IEC AC Rate: AC-1.
- 8 kW. Electric e strength: 4 kV. Operating Temperature -30…+70 °C (-22…+158 °F). Dimensions (approx.): 54 x 64 x 84 mm / 2.1'' x 2.5'' x 3.3'' (Length x Width x Height).
- DIN RAIL – Standard mounting support for any electromechanical component, including contactors, using the DIN specificatio....
Check StockTrane • 40 Amp 1 Pole 24v Coil Packard Replacement Contactor C140A
- 200K cycles UL testing approval for Dp contactor.
- Replace SIEMENS 45 series dp contactor 1 pole 40FLA 24V coil.
- UL,CUL CSA, SEV S+, CE Approved AC contactor.All our DP contactors series meet the ARI Standard 780/790-1997 and UL508 standard.
- Replacement parts number: 8910DP41V14, 3100-15Q19, C25ANF140T, 45GG10AJA,HCCY1XQ04GG, C140A, DP40241..
Check StockToToT 2pcs QP-02-4.7 PTC Refrigerator Start Relay 4 Pin Coolers Compressor Starter 4.7 ohm High Quality Refrigerator Compressor PTC Starter
- Production Name: Air Conditioner Contactor, Poles: 2P, Rated Current: 40 FLA Amp, Coil Voltage:24V AC, Terminal Size: 1/4 in Standard, Max.Withstand Voltage: 600V AC.
- Directly replace Mars 17421 Siemens 45GG20AJ cutler-hammer C25BNB240T Hartland controls HCCY2XQ04GG303.
- The contactor has heavy lug screws terminal and 4 pcs male 1/4 in standard terminals for quick connect, convenient for your fast replacement.
- Very easy to install and replace, save your time and energy.
- Fully enclosed contacts ensure safe,copper contact points make perfect and durable.
Check StockPaddsun 12V Solenoid Relay Contactor & Winch Rocker Thumb Switch Combo for ATV UTV with 6 Protecting Caps
- Replacement 12V Solenoid Relay Contactor & Winch Rocker Thumb Switch Combo for ATV UTV..
- Fitment: for ATV Winch Solenoid Relay Contactor Switch..
- Package Includes: 1 x 12V Winch Solenoid Relay Contactor, 1 x Winch Contactor Rocker Thumb Switch, 1 Set of Mounting Brackets, 6 x Insulated Protecting Waterproof Caps..
- Fast ships from TX/CA warehouse,handing time within 24h in business days..
Check StockAir Vent Ventilation for Motorhome, Maso Cooling Exhaust Fan 12V for RV Caravan
- side vent deflector Applicable to the vast majority of rv..
- bus ceiling air conditioning vent Made of high material, durable and reliable..
- conditioning vent outlet The product is ergonomic in design and easy to install..
- air conditioning deflector outlet RV universal air conditioning outlet..
Check Stock20 in. x 20 in. x 1 in. Basic Household Pleated Air Filter (3-Pack)
- This is a Brand New Upgraded 1 Pole 30 Amp Condenser Contactor.
- This contactor is rated for 30 amps, meaning it is an upgrade for old 25 amp contactors.
- The coil is rated for 24 volts- It also has a sealed contact!.
- This contactor will work with 99% of residential units!.
Check StockOneTrip Parts Furnace Pressure Switch High Temp Tubing 3/16 I.D. X 18\ Replaces Rheem Ruud Weatherking 79-21491-83
- This is a Brand New Upgraded 1 Pole 40 Amp Condenser Contactor.
- This is a Heavy Duty contactor rated for up to 40 Amps!.
- This contactor will work with 99% of residential units!.
Check Stock12V 250A Winch Solenoid Relay Contactor Thumb Truck for ATV UTV 2000-5000lbs Winch with 6 Protecting Caps - Ovsor
- 【PRODUCT PARAMETER】- Voltage - 12V, power – 250A, capacity - 2000-5000lbs, for ATV Winch Solenoid Relay Contactor Switch 12V 250 AMP 1500lb-5000lb Application..
- 【HIGH QUALITY】 - Made of strong, weather-resistant steel and powder-coated black surface, with super durability. OEM of high quality KFI winch kit is a great alternative to replace contactor..
- 【MULTIFUNCTIONAL APPLICATION】- For ATV Winch Solenoid Relay Contactor Switch 12V 250 AMP 1500lb-5000lb Application. Direct Replacement for UTV ATV Winch Solenoid Relay Contactor Switch 12V 250 AMP..
- 【INSTALLATION GUIDE】- Easy to install. The two wires - Green and Black which go to the switch that controls In and Out on a winch. Blue and yellow go to motor, Black and red go to battery..
- 【AFTER-SALES SERVICE】- If the product fails or other problems, you can contact us at any time, we will solve the problem for you within 12 hours..
Check Stock