Reviews 5amp Contactor 2volt Coil
Electrodepot 40 Amp 4 Pole Normally Closed Contactor, 110-120V Coil, Motor Load 20A, Lighting 40A Bundle with Slotted Steel Zinc Plated DIN Rail, 35 mm x 6 in – 1 Piece with 2 Number 10 Screws
- BUNDLE CONTENT: 4 ITEMS – One (1) 40A Contactor, one (1) compatible Slotted Steel Zinc Plated DIN Rail and two (2) drive stainless steel truss head screws (#10, 1/2") for immediate installation.
- APPLICATIONS – Lighting, motor or switching. AC-1 for resistance furnaces, incandescent lamps or electric heaters.
- and AC-3 for air conditioners, compressors or fans. 24/120/220/277 V, with an energy saving, silent and no humming coil.
- COIL VOLTAGE AND LOAD – Contactor IEC 400V. Coil Voltage 110/120VAC, 50/60 Hz.
- Coil load Inrush 30VA, Sealed 4VA. Inductive/Motor Load: 20Amp, Resistive/Incandescent Load: 40Amp. DC Load: 30Amp @ 24VDC. Compatible with 20 Amp, 30 Amp, 32 Amp and 40 Amp loads. Power Lug Terminal Capacity AWG # 4.
- OTHER CONTACTOR DETAILS – Contactor type NC with 4 poles, power status indicator. IEC AC Rate: AC-1.
- 8 kW. Electric e strength: 4 kV. Operating Temperature -30…+70 °C (-22…+158 °F). Dimensions (approx.): 85 x 45 x 92 mm / 3.4'' x 1.7'' x 3.6'' (Length x Width x Height).
- DIN RAIL – Standard mounting support for any electromechanical component, including contactors, using the DIN specifications adopted by European (EN) and international (IEC) standards. Standard width 34.9mm (1.375”) length 152.40mm (6”) and t....
Check StockElectrodepot 40 Amp 12 Pole (4 Pole x 3) Normally Open, 110-120VAC Coil (Silent Operation), Motor Load 40A and Lighting Load 63A Contactor Bundle with 8\ DIN Rail and 2 Number 10 Screws
- BUNDLE CONTENT: 6 ITEMS – Three (3) 40A 4 Pole Normally Open (NO) Contactors with power status indicator.
- one (1) compatible Slotted Steel Zinc Plated 35mm x 200mm DIN Rail and two (2) stainless steel truss head screws (#10, 1/2") for immediate home or industrial installation.
- CONTACTOR APPLICATIONS – Lighting, motor or switching. AC-1 for resistance furnaces, incandescent lamps or electric heaters.
- and AC-3 for air conditioners, compressors or fans. 24/120/220/277 V, with an energy saving, silent and no humming coil.
- COIL VOLTAGE AND LOAD – Contactor IEC 400V. Coil Voltage 110/120VAC, 50/60 Hz.
- Coil load Inrush 52VA, Sealed 10VA. Inductive/Motor Load: 40Amp, Resistive/Incandescent Load: 63Amp. DC Load: 30Amp @ 24VDC. Compatible with 15 Amp, 20 Amp, 30 Amp, 32 Amp, 40 Amp, 50 Amp, 60 Amp and 63 Amp loads. Power Lug Terminal Capacity AWG # 4.
- OTHER CONTACTOR DETAILS – Contactor type NO with 4 poles, power status indicator. IEC AC Rate: AC-1.
- 8 kW. Electric e strength: 4 kV. Operating Temperature -30…+70 °C (-22…+158 °F). Dimensions (approx.): 54 x 64 x 84 mm / 2.1'' x 2.5'' x 3.3'' (Length x Width x Height).
- DIN RAIL – Standard mounting support for any electromechanical component, including contactors, using the DIN specificat....
Check StockElectrodepot 40 Amp 8 Pole (4 Pole x 2) Normally Open, 110/120VAC Coil (Silent Operation), Motor Load 40A and Lighting Load 63A Contactor Bundle with DIN Rail, 35 x 150 mm and 2#10 Screws
- BUNDLE CONTENT: 5 ITEMS – Two (2) 40A 4 Pole Normally Open (NO) Contactors with power status indicator.
- one (1) compatible Slotted Steel Zinc Plated 35mm x 150mm DIN Rail and two (2) stainless steel truss head screws (#10, 1/2") for immediate home or industrial installation.
- CONTACTOR APPLICATIONS – Lighting, motor or switching. AC-1 for resistance furnaces, incandescent lamps or electric heaters.
- and AC-3 for air conditioners, compressors or fans. 24/120/220/277 V, with an energy saving, silent and no humming coil.
- COIL VOLTAGE AND LOAD – Contactor IEC 400V. Coil Voltage 110/120VAC, 50/60 Hz.
- Coil load Inrush 52VA, Sealed 10VA. Inductive/Motor Load: 40Amp, Resistive/Incandescent Load: 63Amp. DC Load: 30Amp @ 24VDC. Compatible with 15 Amp, 20 Amp, 30 Amp, 32 Amp, 40 Amp, 50 Amp, 60 Amp and 63 Amp loads. Power Lug Terminal Capacity AWG # 4.
- OTHER CONTACTOR DETAILS – Contactor type NO with 4 poles, power status indicator. IEC AC Rate: AC-1.
- 8 kW. Electric e strength: 4 kV. Operating Temperature -30…+70 °C (-22…+158 °F). Dimensions (approx.): 54 x 64 x 84 mm / 2.1'' x 2.5'' x 3.3'' (Length x Width x Height).
- DIN RAIL – Standard mounting support for any electromechanical component, including contactors, using the DIN specificatio....
Check StockTrane • 40 Amp 1 Pole 24v Coil Packard Replacement Contactor C140A
- 200K cycles UL testing approval for Dp contactor.
- Replace SIEMENS 45 series dp contactor 1 pole 40FLA 24V coil.
- UL,CUL CSA, SEV S+, CE Approved AC contactor.All our DP contactors series meet the ARI Standard 780/790-1997 and UL508 standard.
- Replacement parts number: 8910DP41V14, 3100-15Q19, C25ANF140T, 45GG10AJA,HCCY1XQ04GG, C140A, DP40241..
Check Stock20 in. x 20 in. x 1 in. Basic Household Pleated Air Filter (3-Pack)
- This is a Brand New Upgraded 1 Pole 30 Amp Condenser Contactor.
- This contactor is rated for 30 amps, meaning it is an upgrade for old 25 amp contactors.
- The coil is rated for 24 volts- It also has a sealed contact!.
- This contactor will work with 99% of residential units!.
Check StockOneTrip Parts Furnace Pressure Switch High Temp Tubing 3/16 I.D. X 18\ Replaces Rheem Ruud Weatherking 79-21491-83
- This is a Brand New Upgraded 1 Pole 40 Amp Condenser Contactor.
- This is a Heavy Duty contactor rated for up to 40 Amps!.
- This contactor will work with 99% of residential units!.
Check StockReplacement for Mars Double Pole / 2 Pole 40 Amp 240v Condenser Contactor Relay 91323
- This is a Brand New Upgraded 2 Pole 40 Amp Condenser Contactor.
- This is a "Heavy Duty" contactor rated at 40 Amps!.
Check StockOEM Trane Upgraded Furnace Control Circuit Board CNT02183
- Genuine OEM Contactor , Factory Component.
- Commonly Used in Various American Standard / Trane Units.
- Replaces / Supersedes: CTR1358 , CTR01358 , CTR-1358 , CTR1273 , CTR-1273 , CTR01273 , CTR1179 , CTR-1179 , CTR01179 , CTR1057 , CTR-1057 , CTR01057....
Check StockWARN 34977 12V Contactor for Industrial Winch Black
- 12 volt contactor, series wound, with bracket for cover.
- Depending on your mounting bracket, you may need WARN-34971.
- For the following WARN Industrial Winch Models: Series 9 DC, 12v, Series 12 DC, 12v, Series 15 DC, 12v.
Check StockCGele 2 Pole Air Conditioner Contactor 30 Amp 24V Coil,Condenser Contactor Compressor Contactor…
- ★ This is a Brand New Upgraded 2 Pole 30 Amp Condenser Contactor..
- ★ Single Pole / 2 Pole.Heavy Lug Terminals and Push-Ons for High Voltage Connections..
- ★ Enclosed Contacts and Encapsulated 24 Volt Coil..
- ★ This contactor will work with 99% of residential units..
Check Stock